GALAXY VS UPS 60KW 400V
Highly efficient, easy-to-deploy 60kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownerJTFp to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and 3 smart modular high capacity battery strings, expandable to 5 strings for extended runtime. See the battery runtime chart for details.
| General Information | |
|---|---|
| Category | Uninterruptible power supplies |
| Description | GALAXY VS UPS 60KW 400V, 3 INTERNAL 9AH SMART MODULAR BATTERY STRINGS, EXPANDABL |
| Manufacturer | APC by Schneider Electric |
| MSRP | $62,790.00 |
| UNSPSC | 39121011 |
| Main Specifications | |
| ABC Code | B |
| Height | 0.00 |
| Length | 0.00 |
| One Source Flag | YNN N |
| Serialized Flag | N |
| SKU Created Date | 250212 |
| Width | 0.00 |
| Battery | |
| Capacity | 9 Ah |
| Quantity | 3 battery strings (installed) / 5 (supported) |
| Technology | Lead acid |
| Type | Expandable |
| Voltage Provided | 480 V |
| Dimensions & Weight | |
| Depth | 84.7 cm |
| Height | 197 cm |
| Weight | 245 kg |
| Width | 55 cm |
| Dimensions & Weight (JTFpping) | |
| JTFpping Depth | 101 cm |
| JTFpping Height | 208.2 cm |
| JTFpping Weight | 270 kg |
| JTFpping Width | 75.5 cm |
| Environmental Parameters | |
| Humidity Range Operating | 0 - 95% (non-condensing) |
| Max Operating Temperature | 40 °C |
| Min Operating Temperature | 0 °C |
| Sound Emission | 54 dBA |
| Expansion / Connectivity | |
| Interfaces | Management (Ethernet) |
| General | |
| Bundled Services | Start-Up Service 5X8 |
| Device Type | UPS - external |
| Manufacturer Warranty | |
| Service & Support | Limited warranty - 2 years - on-site |
| Miscellaneous | |
| Compliant Standards | IP20, FCC Part 15 A, IEC 62040-1-1, IEC 62040-2, RoHS, REACH |
| Features | Parallel Capability, built-in static bypass, audible alarm, touch screen LCD display |
| Included Accessories | Dust filter |
| Networking | |
| Remote Management Interface | Ethernet |
| Remote Management Protocol | SNMP, Modbus |
| Power Device | |
| Efficiency | 96% at 25% Load, 96.7% at 50% Load, 96.7% at 75% Load, 96.6% at 100% Load |
| Frequency Provided | 50/60 Hz ± 0.1% |
| Frequency Required | 40 - 70 Hz |
| Input Voltage | AC 380/400/415 V |
| Input Voltage Range | AC 340 - 460 V |
| Input Wiring | 3-phase |
| Output Voltage | AC 380/400/415 V ± 1% - 50/60 Hz |
| Output Waveform | Sinewave |
| Power Capacity | 60 kW / 60000 VA |
| Power Factor (PF) | 0.99 |
| Total Harmonic Distortion (THD) | 1 % |
| UPS Technology | On-line |
Write Your Own Review