APC SBP16KRMP4U-HW Service Bypass Panel 200/208/240V | Rack Mount — SBP16KRMP4U-HW

Availability: Out of stock
SKU
SBP16KRMP4U
UPC Code
731304212669
Questions before you move forward?

Chat with a JTF expert in Springfield, VA.

Click and connect instantly.

secure transactionsecure transaction
Maintain uptime when UPS service cannot wait. The APC SBP16KRMP4U-HW service bypass panel is built for Symmetra LX environments running 200/208/240 V at 4-16 kVA, giving infrastructure teams a direct path to keep connected loads energized during maintenance or replacement work. Its outlet mix is designed for practical deployment: one L14-30R, three L5-20R, and one 100 A hardwire connection support a range of downstream equipment and installation requirements. That flexibility matters in real data center and edge environments where load profiles rarely match a single receptacle type. For teams responsible for availability, the value is straightforward: isolate the UPS without taking the protected load down. That reduces maintenance risk, shortens service windows, and helps preserve operational continuity in environments where even brief interruptions carry cost. This panel is a purpose-built accessory for Symmetra LX power architectures, not a generic distribution device. It is intended for organizations that need a dependable bypass path, clean service procedures, and the confidence that critical systems can stay online while power infrastructure is being worked on. Ideal For Bypass a Symmetra LX UPS during scheduled maintenance without interrupting connected loads Support replacement work in a data center power chain where uptime must be preserved Provide a controlled service path for mixed receptacle and hardwired equipment Reduce outage exposure during UPS inspection, repair, or battery-related service Why This Product 1 Purpose-built for Symmetra LX service continuity 2 Supports mixed receptacle and hardwire connections 3 Rated for 4-16 kVA power environments 4 Designed to keep loads energized during UPS maintenance
  • Input Voltage: 200/208/240 V
  • Rack Units: 4 U
  • Form Factor: Rack mount
  • Mounting Type: Rack mount
  • Outlet Type: L14-30R, L5-20R, hardwire
  • Outlet Count: 5
  • Pdu Type: Service bypass panel
  • Max Amps: 100 A
  • Input Plug Type: Hardwire
  • Pdu Plug Type: Hardwire
  • Pdu Va Rating: 4-16 kVA
  • Pdu Mount Type: Rack mount
  • Pdu Outlet Type: L14-30R, L5-20R
  • Pdu Outlet Count: 5 outlets
  • Pdu Input Voltage: 200/208/240 V
  • Key Feature 1: Service bypass panel for APC Symmetra LX UPS systems
  • Key Feature 2: Supports 200/208/240 V input
  • Key Feature 3: Rated for 4-16 kVA Symmetra LX configurations
  • Key Feature 4: Includes one L14-30R outlet
  • Key Feature 5: Includes three L5-20R outlets
  • Key Feature 6: Includes one 100 A hardwire connection
  • Key Feature 7: Designed for maintenance continuity in critical power environments