APC NetShelter Rack PDU Advanced
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.





















- APC NetShelter Rack PDU Advanced (APDU10151ME): Plan for an always-changing future. Power distribution adds a layer of complexity to IT deployments. Because every device needs the right amount of power and the right type of outlet, adding or upgrading PDUs (or finding out you have the wrong type) slows down deployment and can create unexpected costs. Choose a rack power distribution unit (PDU) that helps you keep up —and be prepared for the future. Designed with high density, speed of deployment, and an "always-on" mentality in mind, APC NetShelter Advanced Rack Power Distribution (PDU) is Schneider Electric's latest innovation in intelligent Rack PDUs for data center environments.
- 4-in-1 combination outlets: Innovative combination C13/C15/C19/C21 outlet for many rack layouts, configurations, & refreshes.
- Local manufacturing: Enabling increased product availability and ability to offer configure-to-order options.
- Configure-to-order capabilities: Configure-to-order options available including color, different input cord lengths and types all done locally for faster delivery timeframes.
- 2x the outlets: Up to 48 outlets to accommodate ever-increasing number of devices in each rack.
- 50% more power: Some models support up to 43.5kW (34.6kW de-rated for NAM) for most any density deployment.
- Space saving form factor: More outlets and more density in a 2.2in single width PDU.
- Live swap NMC: Live swappable network management card (NMC) allows for uptime even in a power event.
- Display power sharing: Maintain access to PDU data and operations during a power event by leveraging adjacent NMC.
- Up to 8 sensors*: Support up to eight sensors to monitor and protect PDU and IT devices from environmental threats. *Sensors expected late 2022.
| General Information | |
|---|---|
| Category | Rack systems for rack mount electroni... |
| Description | APC NetShelter Rack PDU Advanced - Power distribution unit (rack-mountable) - metered - AC 200-240 V - 5 kW - 5000 VA - 1-phase - Ethernet 10/100/1000 - input: NEMA L6-30P - output connectors: 40 (20 x IEC 60320 C13/C15, 20 x IEC 60320 C13/C15/C19/C21) - 0U - 3 m cord - black |
| Manufacturer | APC by Schneider Electric |
| MSRP | $2,490.00 |
| UNSPSC | 24102001 |
| Main Specifications | |
| Dimensions & Weight / Depth | 7.5 cm |
| Dimensions & Weight / Height | 149 cm |
| Dimensions & Weight / Weight | 6.6 kg |
| Dimensions & Weight / Width | 5.6 cm |
| Header / Brand | APC |
| Miscellaneous / Product Color | Black |
| Networking / Remote Management Interface | Ethernet 10/100/1000 |
| Packaged Quantity | 1 |
| Power Device / Form Factor | Rack-mountable |
| Power Device / Output Connector Qty | 40 |
| Power Device / Power Capacity (VA) | 5000 VA |
| Power Device / Voltage Required | AC 200-240 V |
| Product Type | Power distribution unit |
| Service & Support / Type | 3-year warranty |
| Dimensions & Weight | |
| Depth | 7.5 cm |
| Height | 149 cm |
| Weight | 6.6 kg |
| Width | 5.6 cm |
| Dimensions & Weight (JTFpping) | |
| JTFpping Depth | 11.6 cm |
| JTFpping Height | 172 cm |
| JTFpping Weight | 8.6 kg |
| JTFpping Width | 20.8 cm |
| Environmental Parameters | |
| Humidity Range Operating | 5 - 95% |
| Max Operating Temperature | 60 °C |
| Min Operating Temperature | -5 °C |
| Expansion / Connectivity | |
| Interfaces |
|
| General | |
| Color | Black |
| Cord Length | 3 m |
| Device Type | Power distribution unit - rack-mountable |
| Height (Rack Units) | 0U |
| Manufacturer Warranty | |
| Service & Support | Limited warranty - replace or repair - 3 years |
| Miscellaneous | |
| Cables Included | Power cable 3 m |
| Compliant Standards | FCC Part 15 Subpart B, UL 62368-1, EN 62368-1, UKCA, CSA C22.2 No. 62368-1, REACH |
| Features | Vertical orientation, overload protection, LCD display |
| Networking | |
| Remote Management Interface | Ethernet 10/100/1000 |
| Remote Management Protocol | SNMP |
| Power Device | |
| Frequency Required | 50/60 Hz |
| Input Connectors | 1 x power NEMA L6-30P |
| Input Voltage | AC 200-240 V |
| Input Wiring | 1-phase |
| Max Electric Current | 30 A |
| Output Voltage | AC 208 V |
| Power Capacity | 5 kW / 5000 VA |
| Power Output Connectors Details |
|
Write Your Own Review